    [COVID-19] PLASMA STERILIZER (HPS-50)
    Recommended for small and medium hospitals. Suitable to sterilize long surgical instruments. Compact design maximizing usability and convenience.
    Product : Plasma Sterilizers (Low Temperature Plasma Sterilizers)
    Manufacturer : Healthwell Medical, Inc.
    Manufacturer Country : KOREA



    Details

    This product generate vacuum plasma inside the sterilization chamber to add Hydrogen Peroxide gas, which will decompose into OH radicals. These OH radicals kill microorganisms on the medical instruments which are heat and moisture sensitive. After sterilization, only water and oxygen will be left inside the sterilization chamber. And you can use the instruments immediately once the sterilization process is completed. Unlikely other sterilization technologies using harmful gases, a long process of removal of residual gas is not necessary.

    Ideal for small medical institutions such as dentistry, ophthalmology, otolaryngology, and veterinary hospitals Designed to ensure user convenience and space efficiency with or without exclusive cart option.

    1. 1. Easy to use
     You can start/cancel/control the sterilization process by simply pressing the key buttons.
     The selected sterilization cycle will be progressed automatically and you can monito 
     relevant information such as sterilization conditions, progress status, error messages from the display.

    2. Automatic notification system for regular maintenance
      This product automatically notifies the replacement period for consumables such as pump oil,
      oil mist trap and air filter. It displays an error message to replace the consumable once it
      reaches 250 cycles. If the consumable is not replaced until it reaches 300 cycles,
      it will stop operation to prevent further equipment failure.

    3. Built-in self-test
      When a malfunction occurs during operation, an error code is displayed by built-in self-test and 
      the running cycle is terminated automatically for safety.

    4. Validation of Sterilization of HPS-30,50
     A PCD(Process Challenge Device) in accordance with EU standards(EN 867-5) is used for
     the validation sterilization of a dead-end lumen at the most difficult positions inside of the 
     sterilization load.
     Test mode : Special Mode(Lumen Mode)
     Lumen Size : HPS-30,50 (1∅×1,000mm(L), Teflon)



    Specifications

    Sterilizing Agent : Hydrogen Peroxide, 1Cycle/Cartridge
    Total Cycle Time : Smart Mode : 40min                  
                             Standard Mode : 48min                 
                             Special Mode : 56min
    Cycle Temperature : 45℃~60℃
    SAL(Sterility Assurance Level) : 10⎺⁶ (Bacillus)
    By-products : Oxygen and vapor water only
    Chamber : Shape : Rectangular
                  Material : Aluminum          
                  Volume : Total : 50L
    Dimensions : Overall : 594×525×890(W×H×D)mm            
                      Chamber : 338×236×660(W×H×D)mm
    Weight : 110kg
    Control : 32bit Micro Processor
    Cycle Information : 2.7” (OLED) Display, Printer
    Electrical : AC 220-230V~, 50Hz, Max 3.0kw
    Installation Requirements : Front : 100cm                      
                                       Rear, Left side, Right side : 5cm                   
                                       Placement : Built-in wheels provide mobility(Option Cart)
    Room Conditions : Use Environment : 10~40℃, 30~75%RH                  
                              Installation Environment : -20~60℃, 0~95%RH
    Printer : Built-in Thermal Printer(Brief Mode / Detail Mode)         
               Cycle Parameters(Temp, Pressure, Time, Daily&Total Cycle, etc)
    Cart(Option) : 613×880×850(W×H×D)mm


    Consumables

    ● Sterilant Cartridges
       (Hydrogen Peroxide 50%)
       1 cartridge/cycle
    ● Packing
       Tyvek Pouch
       Non-Woven Sheet
       Impulse Sealer
    ● Maintenance*
        Vacuum Oil
        Oil Mist Trap

    *Recommend to be changed every 250 cycles. However, the number of cycles can vary according to
    daily practices of users in terms of sterilization loads(types, quantity, moisture content) and frequency
    of sterilization and etc.

    ● Sterilization Monitoring
        CI(Chemical Indicator) : to monitor if the sterilization loads are exposed to H2O2 by a color change.
        BI(Biological Indicator) : to monitor if the sterilization is successful by an incubation of bacillus.
    ● Exclusive Cart(Option)
        HPS-50 : 613×880×850(W×H×D)mm